         UL94 flame retardant rating test

        UL94 flame retardant rating is the most widely used material flame retardant performance evaluation standard. It is used to evaluate the ability of materials to extinguish after being ignited and is a commonly used standard for daily testing of material flame retardancy. There are multiple evaluation methods for UL94 based on the combustion rate, combustion time, droplet resistance, and whether the droplets burn after ignition of the material.

         

        UL94 has a total of 12 levels:

         

        HB, V-0, V-1, V-2, 5VA, 5VB, VTM-0, VTM-1, VTM-2, HBF, HF1, HF2。

         

        Among them, VTM-0, VTM-1, and VTM-2 are suitable for plastic film, while HBF, HF1, and HF2 are suitable for foam materials

         

        The level testing plan is as follows:

        1) HB level: Horizontal Burning Test

        2) V0-V2 level: Vertical Burning Test

        3) 5VA/5VB: 5V level fire test 500w (125 mm) vertical burning test

        4) RP Class: Radiant Panel Flame Spread Test

        5) VTM0-VTM2: Thin Material Vertical Burning Test

        6) HF1-HF2: Horizontal Burning Foam Material Test

         

        The specific testing requirements for UL94 are as follows:

         

        HB: Flame retardant rating in UL94 standard. Require a combustion rate of less than 40 millimeters per minute for samples with a thickness of 3 to 13 millimeters; Samples less than 3 millimeters thick have a combustion rate of less than 70 millimeters per minute; Or extinguish before the 100mm mark.

         

        V-0: After conducting two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 30 seconds. Dropping particles cannot ignite cotton.

         

        V-1: After conducting two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dropping particles cannot ignite cotton.

         

        V-2: After two 10 second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dripping particles can ignite cotton.

         

        5VB: After conducting five 5-second combustion tests on the sample, the residual flame and residual flame will extinguish within 60 seconds. Dropping particles cannot ignite cotton. For block samples, it is allowed to be burned through.

         

        5VA: After conducting five 5-second combustion tests on the sample, the residual flame and residual flame will extinguish within 30 seconds. Dropping particles cannot ignite cotton. It is not allowed to burn through block samples.

         

        Common UL94 testing methods

        1. Horizontal Combustion Test (HB)

        2. 50W vertical combustion test

        3.500W vertical combustion test

         

        UL 94 Flame Retardant Rating Criteria

        1. UL94 horizontal combustion judgment conditions


        Burning rate

        Flame retardant rating

        Sample thickness 3-13mm

        40mm/min

        HB

        Sample thickness 3mm

        75mm/min

        HB

        The flame goes out before the marking   line

        =0 mm/min

        HB

        2. UL94 vertical combustion judgment conditions

        Judgment condition

        V-0

        V-1

        V-2

        Spontaneous combustion time after   applying flames

        10

        30

        30

        Total self ignition time (s)

        (10   spontaneous combustion times)

        50

        250

        250

        Spontaneous combustion after the second   flame application

        +Crimson time (s)

        30

        60

        60

        Droplets ignite cotton

        no

        no

        yes

        Burn to fixture (sample completely   burned)

        no

        no

        no

        3. UL94 500w vertical combustion judgment conditions


        5VA

        5VB

        Any sample spontaneously ignites after 5   flame applications+Crimson time (s)

        60

        60

        Droplets ignite cotton

        no

        no

        Sample perforation ( 3mm)

        no

        yes

         

        Please consult NormalTCI for specific questions

        National Unified Service Hotline: 400-6177-880

        Email [email protected]

        Copyright @ 2015 NORMAL (HANGZHOU) TESTING & CERTIFICATION CO., LTD.  

        Tell:+86-571-28906690  E-mail:[email protected]  Service Hotline:400-6177-880  Fax:+86-571-28867000

        If you have any comments on the website, please email to:[email protected]

      1. <cite id="4k6vu"><listing id="4k6vu"></listing></cite>
      2. 
        
          <dd id="4k6vu"></dd>
            <ul id="4k6vu"><th id="4k6vu"></th></ul>
            <cite id="4k6vu"></cite>

            成人精品视频在线 | 成人青青草 | 久久久久久网站 | 高中男男gay互吃鳮 | 成人一区二区三区在线A片 |